    Technical requirements 

    1. Research Methods: Bright Field, Simple Polarization 
    2. Optical system: “Infinite” optical system with a parfocal distance of at least (mm) 60 
    3. A quick refocusing system that allows you to instantly lower the stage by pressing on it to replace the sample or apply immersion oil to the glass slide. If you remove your hand from the table, it returns to its original position. Availability 
    4. Lighting: Halogen Lamp 
    5. Lamp power, not less (W) 30 
    6. Lamp voltage, no more (V) 6 
    7. Trinocular tube with the possibility of dividing the light flux in a ratio of 100/0; 0/100 Availability 
    8. The angle of the eyepiece tube, at least 30 ° 
    9. Lower value of the interpupillary distance adjustment range, no more (mm) 47 
    10. Upper value of the interpupillary distance adjustment range, not less (mm) 74 
    11. The ratio of the increase in eyepieces, X 10 
    12. Field of view of the eyepiece, not less than (mm) 20 
    13. The number of positions in the lens revolver, not less (pcs.) 4 
    14. Item table Availability 
    15. The width of the stage, not less than (mm) 200 
    16. The length of the stage, not less (mm) 135 
    17. The range of movements of the stage: along the X axis, not less (mm) 75 
    18. The range of movements of the stage: along the Y axis, not less (mm) 50 
    19. Capacitor Abbe, with a numerical aperture, not less than 1.25 
    20. Planachromatic lens class 
    21. Lens Kit: 
      1. Planachromatic lens with magnification not more than 4x, numerical aperture not less than 0.1, working distance not less than 30.0 mm, (pcs.) Availability 
      2. Planachromatic lens with magnification not more than 10x, numerical aperture not less than 0.25, working distance not less than 7.0 mm, (pcs.) Availability 
      3. Planachromatic lens with magnification not more than 40x, numerical aperture not less than 0.65, working distance not less than 0.65 mm, (pcs.) Availability 
      4. Planachromatic lens with an increase of at least 100X oil immersion, a numerical aperture of at least 1.25, a working distance of at least 0.23 mm, with a spring mechanism, (pcs.) Availability 
    22. Resolution of the matrix, not less (MPix) 5 

    * The item is new. Warranty period is out.

    Specifications

    Make a request

    We will surely contact you

    First name Last name*

    Phone number *

    Fields marked with * are required

    Ведущий интегратор 3D-решений в России и СНГ Контакты:
    Адрес: ул. Рочдельская, д. 15, стр. 21 123376 Москва,
    Телефон:+7 495 374 60 07, Факс:+7 495 374 60 07, Электронная почта: info@siusystem.ru